BOE DV215FHM-R10
BOE DV215FHM-R10 is a 21.5 inch, 1920 × 1080 FHD commercial display module with 1500 nit high brightness, LVDS interface and an operating range of -20 ~ 80 °C.
No stock photos on file for this model yet. Send an enquiry and we will shoot the actual label, front and rear of the batch before you commit.
Key parameters
| Panel maker | BOE |
| Model | DV215FHM-R10 |
| Category | Commercial display panel |
| Size | 21.5″ |
| Resolution | 1920 × 1080 FHD (16:9) |
| Interface | 2-port LVDS 51 pins (CI1406M1VL0) |
| Brightness | 1500 cd/m² (typ., min 1200) |
| Operating temp. | -20 to 80 °C (absolute maximum rating) |
| Contrast | 1000:1 (typ., min 700) |
| Connector | CI1406M1VL0-NH (CviLux) |
| Colour gamut | 72% NTSC (typ.) |
| Surface | Anti-glare, 3H |
| LED lifetime | 50,000 h |
| Storage temp. | -30 to 80 °C |
| Outline | 499 × 286.2 × 10.7 mm |
| Weight | 2.0 kg |
| Spec status | Rev P0(2022-02-14) |
Sourcing notes
Measurement caveats: 1500 nits is the Typ value at 25 °C; the -20 ~ 80 °C operating range is the TOP field from the absolute maximum ratings chapter - a boundary that must not be exceeded, not a guarantee of full performance at both ends. The sheet carries no high-temperature luminance curve; run thermal simulation before fixing backlight strategy in outdoor enclosures.
Verified against a preliminary datasheet (2022-02-14); confirm the released revision before volume orders. Tell us whether you need the bare panel, a backlight-integrated unit or a full mechanical module - the three quote differently.
Where this panel is used
- Outdoor and semi-outdoor kiosks1500 cd/m² is the number that decides this one. Above roughly 650 nits the panel stays readable in direct sun with the backlight dialled to 60-70%, which is how outdoor enclosures are normally configured to keep backlight life inside spec. The enclosure still has to carry the heat: size the air path or the sunshade for the full backlight load, not for a 50% duty cycle.
- Cold-start and wide-temperature equipmentThe operating range covers −20 to +80 °C. The datasheet lists that range under absolute maximum ratings, so read it as the boundary the panel has to stay inside rather than a promise of full performance at both ends, and check the panel-surface limit in the parameter table: in a sealed cabinet that figure, not the ambient one, is usually what decides the design. Standard commercial panels stop at 0-50 °C, so below freezing they either refuse to start or lose response time badly enough to look like a dead driver board — which is why refrigerated display, vehicle-mounted terminals and winter-start outdoor cabinets shortlist a wide-temperature part in the first place.
- Vehicle-mounted and ruggedised terminalsIn-cab displays, agricultural and construction machinery, and ruggedised field terminals. Vibration and shock dominate the qualification here rather than temperature alone: the module has to survive the mounting bracket resonating. Ask for the shock and vibration ratings in the datasheet and match them to the vehicle class before you commit, and specify a locking connector on the harness side.
- Industrial HMI and machine-side panelsMachine, packaging-line and test-bench HMI. On a 21.5-inch diagonal, a 1920 × 1080 FHD canvas fits an alarm banner, a trend curve and a recipe panel on one screen, which is what operators actually need at arm's length. These cabinets are hostile to displays — vibration, 25-40 °C internal air, continuous duty for years — so mount the module on standoffs and keep the rear air gap that the mounting drawing specifies.
Matching it to your platform
- Channel count and pin countLVDS modules come as single-channel ( pin is common) or dual-channel (often 51 pin). A cable built for one will not seat on the other, and the host transmitter has to drive the same number of pairs. Confirm both before the harness is made.
- VESA or JEIDA mappingThe two pinout families assign the data pairs differently. Feeding a VESA-mapped panel with a JEIDA-mapped transmitter produces a recognisable colour-shifted image rather than no image, so it is easy to misdiagnose as a panel fault.
- DE-only or separate syncMost industrial LVDS panels run in DE-only mode: Hsync and Vsync have to be tied low or grounded at the host. Feeding separate sync into a DE-only panel gives an unstable or rolling picture.
- Backlight drive and PWMCheck whether the boost converter sits inside the module. If it does, the panel takes a raw DC rail and you do not add a constant-current board — doubling up the driver is a common way to destroy a backlight. Confirm the PWM dimming frequency the converter expects.
- Mechanics and outlineOutline, screw bosses, ear position and FPC exit direction all have to line up with the existing chassis. Compare the mechanical drawing against the mounting surface and hole pitch before tooling anything — this step catches more mismatches than the connector does.