BOE DV215FHM-R10

BOE DV215FHM-R10 is a 21.5 inch, 1920 × 1080 FHD commercial display module with 1500 nit high brightness, LVDS interface and an operating range of -20 ~ 80 °C.

BOE21.5″1920×1080 FHDLVDS1500 nits (typ., min 1200)
Panel maker
BOE
Size
21.5″
Resolution
1920 × 1080 FHD
Interface
LVDS
Photos

No stock photos on file for this model yet. Send an enquiry and we will shoot the actual label, front and rear of the batch before you commit.

Key parameters

Panel makerBOE
ModelDV215FHM-R10
CategoryCommercial display panel
Size21.5″
Resolution1920 × 1080 FHD (16:9)
Interface2-port LVDS 51 pins (CI1406M1VL0)
Brightness1500 cd/m² (typ., min 1200)
Operating temp.-20 to 80 °C (absolute maximum rating)
Contrast1000:1 (typ., min 700)
ConnectorCI1406M1VL0-NH (CviLux)
Colour gamut72% NTSC (typ.)
SurfaceAnti-glare, 3H
LED lifetime50,000 h
Storage temp.-30 to 80 °C
Outline499 × 286.2 × 10.7 mm
Weight2.0 kg
Spec statusRev P0(2022-02-14)

Sourcing notes

Measurement caveats: 1500 nits is the Typ value at 25 °C; the -20 ~ 80 °C operating range is the TOP field from the absolute maximum ratings chapter - a boundary that must not be exceeded, not a guarantee of full performance at both ends. The sheet carries no high-temperature luminance curve; run thermal simulation before fixing backlight strategy in outdoor enclosures.

Verified against a preliminary datasheet (2022-02-14); confirm the released revision before volume orders. Tell us whether you need the bare panel, a backlight-integrated unit or a full mechanical module - the three quote differently.

Where this panel is used

  • Outdoor and semi-outdoor kiosks1500 cd/m² is the number that decides this one. Above roughly 650 nits the panel stays readable in direct sun with the backlight dialled to 60-70%, which is how outdoor enclosures are normally configured to keep backlight life inside spec. The enclosure still has to carry the heat: size the air path or the sunshade for the full backlight load, not for a 50% duty cycle.
  • Cold-start and wide-temperature equipmentThe operating range covers −20 to +80 °C. The datasheet lists that range under absolute maximum ratings, so read it as the boundary the panel has to stay inside rather than a promise of full performance at both ends, and check the panel-surface limit in the parameter table: in a sealed cabinet that figure, not the ambient one, is usually what decides the design. Standard commercial panels stop at 0-50 °C, so below freezing they either refuse to start or lose response time badly enough to look like a dead driver board — which is why refrigerated display, vehicle-mounted terminals and winter-start outdoor cabinets shortlist a wide-temperature part in the first place.
  • Vehicle-mounted and ruggedised terminalsIn-cab displays, agricultural and construction machinery, and ruggedised field terminals. Vibration and shock dominate the qualification here rather than temperature alone: the module has to survive the mounting bracket resonating. Ask for the shock and vibration ratings in the datasheet and match them to the vehicle class before you commit, and specify a locking connector on the harness side.
  • Industrial HMI and machine-side panelsMachine, packaging-line and test-bench HMI. On a 21.5-inch diagonal, a 1920 × 1080 FHD canvas fits an alarm banner, a trend curve and a recipe panel on one screen, which is what operators actually need at arm's length. These cabinets are hostile to displays — vibration, 25-40 °C internal air, continuous duty for years — so mount the module on standoffs and keep the rear air gap that the mounting drawing specifies.

Matching it to your platform

  • Channel count and pin countLVDS modules come as single-channel ( pin is common) or dual-channel (often 51 pin). A cable built for one will not seat on the other, and the host transmitter has to drive the same number of pairs. Confirm both before the harness is made.
  • VESA or JEIDA mappingThe two pinout families assign the data pairs differently. Feeding a VESA-mapped panel with a JEIDA-mapped transmitter produces a recognisable colour-shifted image rather than no image, so it is easy to misdiagnose as a panel fault.
  • DE-only or separate syncMost industrial LVDS panels run in DE-only mode: Hsync and Vsync have to be tied low or grounded at the host. Feeding separate sync into a DE-only panel gives an unstable or rolling picture.
  • Backlight drive and PWMCheck whether the boost converter sits inside the module. If it does, the panel takes a raw DC rail and you do not add a constant-current board — doubling up the driver is a common way to destroy a backlight. Confirm the PWM dimming frequency the converter expects.
  • Mechanics and outlineOutline, screw bosses, ear position and FPC exit direction all have to line up with the existing chassis. Compare the mechanical drawing against the mounting surface and hole pitch before tooling anything — this step catches more mismatches than the connector does.

Questions buyers ask

DV215FHM-R10 is a 21.5-inch 1920 × 1080 FHD LVDS module. Stock moves daily and we do not publish a live count — send the quantity and the date you need it and we check the warehouse against that batch the same day.
Yes. The maker's sheet for the 1920 × 1080 FHD version goes out with the quote, plus label photos and the connector drawing where we hold them. Some revisions are marked tentative by the maker — we state the version and date so you can confirm the released one before a volume order.
There is no fixed MOQ on a 21.5-inch module. It depends on what is on the shelf, the grade you accept and where it ships — tell us the quantity you actually need and the quote answers that, instead of pushing a carton size at you.
The nearest substitutes in the catalogue are P215HAN02.0, DV215FHM-R01 and M215HCA-L3B — ranked on size, resolution, interface and brightness rather than brand. Before committing to one, compare it with the DV215FHM-R10 on connector type, backlight drive method and mounting ear position: those three stop a swap more often than the panel itself.
1500 nits on a 21.5-inch panel works for shaded and semi-outdoor installations with the backlight at 60-70% and an anti-glare surface. Fully exposed summer sun is a different problem — it needs a sunshade and a thermal path sized for the full backlight load, not just a brighter panel.
That is what the −20 to +80 °C rating covers. A standard commercial panel is 0-50 °C and either refuses to start or drifts badly below freezing. For cold-start equipment, let the module settle near its rated low end before running the backlight at full duty.