Innolux · BOE · HKC · CSOT · LG Display · AUO Quote response within 24 hours Cross-border trade · Shenzhen
Home Products
Product lines
LCD Modules Commercial display Touch / Incell High brightness
Company
Panel Sources Solutions Company Contact
Language
中文 Request a quote

BOE P320HVN04.4

BOE P320HVN04.4 is a 31.5 inch, 1920 × 1080 FHD commercial display module with 1500 nit high brightness, 2-channel LVDS (51-pin) interface, an operating range of -20 ~ +60 °C and 24/7 continuous operation.

BOE31.5″1920×1080 FHDLVDS1500 nits (typ., min 1200, at 25 °C)
Panel maker
BOE
Size
31.5″
Resolution
1920 × 1080 FHD
Interface
LVDS
Photos

No stock photos on file for this model yet. Send an enquiry and we will shoot the actual label, front and rear of the batch before you commit.

Key parameters

Panel makerBOE
ModelP320HVN04.4
CategoryCommercial display panel
Size31.5″
Resolution1920 × 1080 FHD (16:9)
Interface2 channel LVDS, 51 pin
Brightness1500 nits (typ., min 1200, at 25 °C)
Connector51-pin LVDS
Operating temp.-20 ~ +60 °C
Contrast4000:1 (typ., min 3200)
Viewing angle89° (CR≥10, per side, typ.)
Colour gamut72% sRGB (typ.)
Response time8 ms (typ., G to G)
SurfaceAG anti-glare, 3H hard coating, haze 28%
Operating time24/7
Backlight lifeLED MTTF 50,000 h
Operating temperature-20 ~ +60 °C
Storage temperature-20 ~ +60 °C
OrientationPortrait/landscape mounting enabled; rotate function unavailable
Outline721.2 × 415.65 × 33.8 mm
DatasheetPreliminary (2022-09) — confirm released revision before volume order

Sourcing notes

The 1500 nit figure is a 25 °C typical value (min 1200) and the datasheet publishes no brightness curve at elevated temperature, so outdoor cabinets need a thermal simulation rather than an assumption that 1500 nits holds across the range. The document also quotes a very wide temperature span for the liquid crystal material itself — that is the material, not the module: the operating range is -20 to +60 °C and anything outside it is not covered by the specification.

Rotate Function is listed as Unachievable, so the panel mounts in either orientation but cannot be rotated in service, and Sunglasses Readability is specified for landscape mode only. The reference copy is a Preliminary revision dated 2022-09 — confirm the released revision and batch before a volume order, and state whether you need a bare panel, a backlight-matched assembly or a full module, since the three are quoted differently.

Where this panel is used

  • Outdoor and semi-outdoor kiosks1500 cd/m² is the number that decides this one. Above roughly 650 nits the panel stays readable in direct sun with the backlight dialled to 60-70%, which is how outdoor enclosures are normally configured to keep backlight life inside spec. The enclosure still has to carry the heat: size the air path or the sunshade for the full backlight load, not for a 50% duty cycle.
  • Cold-start and wide-temperature equipmentThe operating range covers −20 to +60 °C. The datasheet lists that range under absolute maximum ratings, so read it as the boundary the panel has to stay inside rather than a promise of full performance at both ends, and check the panel-surface limit in the parameter table: in a sealed cabinet that figure, not the ambient one, is usually what decides the design. Standard commercial panels stop at 0-50 °C, so below freezing they either refuse to start or lose response time badly enough to look like a dead driver board — which is why refrigerated display, vehicle-mounted terminals and winter-start outdoor cabinets shortlist a wide-temperature part in the first place.
  • Digital signage and window displaysA 31.5-inch panel at 1920 × 1080 FHD is a signage-class canvas: the pixel pitch holds up from three metres and beyond, which is the viewing distance that matters for a freestanding display or a shop window. Sizing is the other half of the job — check the cut-out and the mounting pattern against your chassis before ordering, because enclosures in this size class are not standardised across integrators.
  • Vehicle-mounted and ruggedised terminalsIn-cab displays, agricultural and construction machinery, and ruggedised field terminals. Vibration and shock dominate the qualification here rather than temperature alone: the module has to survive the mounting bracket resonating. Ask for the shock and vibration ratings in the datasheet and match them to the vehicle class before you commit, and specify a locking connector on the harness side.

Matching it to your platform

  • Channel count and pin countLVDS modules come as single-channel (51 pin is common) or dual-channel (often 51 pin). A cable built for one will not seat on the other, and the host transmitter has to drive the same number of pairs. Confirm both before the harness is made.
  • VESA or JEIDA mappingThe two pinout families assign the data pairs differently. Feeding a VESA-mapped panel with a JEIDA-mapped transmitter produces a recognisable colour-shifted image rather than no image, so it is easy to misdiagnose as a panel fault.
  • DE-only or separate syncMost industrial LVDS panels run in DE-only mode: Hsync and Vsync have to be tied low or grounded at the host. Feeding separate sync into a DE-only panel gives an unstable or rolling picture.
  • Backlight drive and PWMCheck whether the boost converter sits inside the module. If it does, the panel takes a raw DC rail and you do not add a constant-current board — doubling up the driver is a common way to destroy a backlight. Confirm the PWM dimming frequency the converter expects.
  • Mechanics and outlineOutline, screw bosses, ear position and FPC exit direction all have to line up with the existing chassis. Compare the mechanical drawing against the mounting surface and hole pitch before tooling anything — this step catches more mismatches than the connector does.

Questions buyers ask

P320HVN04.4 is a 31.5-inch 1920 × 1080 FHD LVDS module. Stock moves daily and we do not publish a live count — send the quantity and the date you need it and we check the warehouse against that batch the same day.
Yes. The maker's sheet for the 1920 × 1080 FHD version goes out with the quote, plus label photos and the connector drawing where we hold them. Some revisions are marked tentative by the maker — we state the version and date so you can confirm the released one before a volume order.
There is no fixed MOQ on a 31.5-inch module. It depends on what is on the shelf, the grade you accept and where it ships — tell us the quantity you actually need and the quote answers that, instead of pushing a carton size at you.
The nearest substitutes in the catalogue are P320HVN04.5, P320HVN04.6 and DV320FHM-NN0 — ranked on size, resolution, interface and brightness rather than brand. Before committing to one, compare it with the P320HVN04.4 on connector type, backlight drive method and mounting ear position: those three stop a swap more often than the panel itself.
1500 nits on a 31.5-inch panel works for shaded and semi-outdoor installations with the backlight at 60-70% and an anti-glare surface. Fully exposed summer sun is a different problem — it needs a sunshade and a thermal path sized for the full backlight load, not just a brighter panel.
That is what the −20 to +60 °C rating covers. A standard commercial panel is 0-50 °C and either refuses to start or drifts badly below freezing. For cold-start equipment, let the module settle near its rated low end before running the backlight at full duty.